Master Plumber’s Mock Exam – CONSTRUIRE https://myconstruire.com Free online reviewers and practice exams, board exam results, reviews and blogs Tue, 11 Oct 2022 02:53:40 +0000 en-US hourly 1 https://wordpress.org/?v=6.4.2 https://myconstruire.com/wp-content/uploads/2022/09/cropped-Construire-32x32.webp Master Plumber’s Mock Exam – CONSTRUIRE https://myconstruire.com 32 32 Free Online Master Plumber Reviewer No. 1 https://myconstruire.com/master-plumber-reviewer-no-1/ https://myconstruire.com/master-plumber-reviewer-no-1/#respond Sat, 24 Sep 2022 15:24:40 +0000 https://myconstruire.com/?p=614 Master Plumber Reviewer No. 1 Check our new Master Plumber Reviewer No. 1 in a new format. This particular reviewer consists of 100 questions. Try our free reviewer in preparation for the upcoming Master Plumber Examination this 2022. Good Luck.

The post Free Online Master Plumber Reviewer No. 1 appeared first on CONSTRUIRE.

]]>
Master Plumber Reviewer No. 1

Check our new Master Plumber Reviewer No. 1 in a new format. This particular reviewer consists of 100 questions. Try our free reviewer in preparation for the upcoming Master Plumber Examination this 2022. Good Luck.

0%

When joints are permitted on a copper tubing that are laid or run underground they shall be____________.

Correct! Wrong!

Changes and direction of drainage piping shall be made by the appropriate use of approve fittings.

Correct! Wrong!

No water closet and bidet shall be set closer than from its center to any side of the wall or obstruction?

Correct! Wrong!

Valve use to prevent the tank from overflowing.

Correct! Wrong!

Horizontal copper tubing, sized 50 mm and larger in diameter shall be supported approximately?

Correct! Wrong!

Clean out may be omitted on a horizontal drain line less than 1.5 m in length except

Correct! Wrong!

All small sized malleable iron water fittings shall be

Correct! Wrong!

Horizontal cast iron soil pipe with a length exceeding 1.5 m in length shall be supported not more than interval

Correct! Wrong!

Drinking fountain should not installed in a?

Correct! Wrong!

Minimum air gaps for water distribution for sinks, laundry trays and other fixtures with effective opening not greater than 19 mm in diameter when affected by the walls.

Correct! Wrong!

Cleanout under floor piping shall have a vertical clearance from means of access not less than

Correct! Wrong!

A valve used to control two or more opening is called ________.

Correct! Wrong!

Continuous waste and fixture tailpiece that such connection where exposed or accessible may be of seamless drawn brass not less than?

Correct! Wrong!

Water pipes and building sewer, and storm drainage constructed on a clay material laid or run in the same trench within a building shall have at least horizontal clearance at all points of ______________.

Correct! Wrong!

Each such tailpiece, continuous waste or overflows for sinks, dishwashers, laundry tubs, bathtubs, urinal and similar fixtures shall not less than?

Correct! Wrong!

No fitting having more than one inlet at the same level shall be used unless the discharge of one inlet cannot enter into the other?

Correct! Wrong!

Gutters and or gang shower room shall be spaced not more than?

Correct! Wrong!

No urinal shall be set closer than from its center to any side of the wall or partition?

Correct! Wrong!

Backflow prevention for hot water over 43.3 °C shall be a listed type assembly design to operate at a temperature of _________ without rendering any portion of the assembly inoperative.

Correct! Wrong!

Water pipes and fittings with a lead content that exceed 8% shall be prohibited and not used in ____________.

Correct! Wrong!

Horizontal screw pipe , sized 25 mm and larger in diameter shall be supported approximately?

Correct! Wrong!

_________ pipes shall have an outside protective coating of an approved material like bituminous coating and fiberglass wrapping.

Correct! Wrong!

Backflow preventers shall not be located in any area containing fumes that are ___________.

Correct! Wrong!

No vitrified clay pipe or fittings for building drain and sewer shall used _________.

Correct! Wrong!

The covers of gravity tank shall be vented with a return bend pipe having an area of not less than the ________.

Correct! Wrong!

Cleanout of an interceptor shall be installed

Correct! Wrong!

Over rim baths filler and other fixtures with effective opening not greater than 25 mm in diameter when not affective by the walls.

Correct! Wrong!

ABS and PVC DWV shall be used for __________.

Correct! Wrong!

Maybe substitute for automatic flush tank?

Correct! Wrong!

Water closet and urinal flushometer valve shall be equipped with a listed __________.

Correct! Wrong!

No urinal shall be set closer than from its center to center of a similar fixtures?

Correct! Wrong!

Fixture having concealed slip joint connection shall be provided with an access panel or utility at least?

Correct! Wrong!

Horizontal cast iron soil pipe with a length not exceeding 1.5 m in length shall be supported not more than interval

Correct! Wrong!

Continuous waste or tailpiece for lavatories, drinking fountain and similar small fixture shall not be less than?

Correct! Wrong!

Horizontal ground piping shall be laid on a firm bed at its _________.

Correct! Wrong!

Ball cock shall be installed with the critical level at least _____ above the full opening of the overflow pipe.

Correct! Wrong!

Relief valve shall be set at a pressure of not more than _________.

Correct! Wrong!

All shower compartments, regardless in shape shall have a minimum finish interior area of?

Correct! Wrong!

Fitting shall be used horizontal to horizontal drainage line

Correct! Wrong!

Water pipes and building sewer, and storm drainage constructed on a clay material laid or run in the same trench within a building shall have at least vertical clearance at all points of ________________.

Correct! Wrong!

Restaurant and other special use sinks may be made of approved type bonderized and galvanized steel sheet of not less than

Correct! Wrong!

Union installed in water supply system shall be installed away from the regulating equipment like water heater, conditioning tank and similar equipment within ___________.

Correct! Wrong!

No under floor cleanout in any residential occupancy shall be located from access door, trap door, or crawl hole more than _________.

Correct! Wrong!

Access and clearance for the backflow prevention assemblies shall require a minimum clearance from a lowest portion of a assembly and the grade floor or platform.

Correct! Wrong!

Prohibited fixtures for a water closet and urinal

Correct! Wrong!

Minimum area and dimension of a shower compartment shall be maintained from a shower drain outlet to a height of _________.

Correct! Wrong!

Cleanout under floor piping shall have a horizontal clearance from the mean of access not less than

Correct! Wrong!

Fittings may be used on vertical lines as a fixture connection

Correct! Wrong!

Vacuum breaker shall be installed at the discharge side of the flushometer valve with the critical level above the overflow rim of a water closet bowl or the highest part of a urinal.

Correct! Wrong!

Joints of copper pans or liners shall be

Correct! Wrong!

Overflow pipe from a fixture shall be connected to the house or

Correct! Wrong!

Air test shall be made for DWV by attaching air compressor to a minimum uniform gauge pressure of_______for the period of ___________.

Correct! Wrong!

The sum of all perforation of the strainer is equivalent to the?

Correct! Wrong!

If water pressure from the main will cannot provide a water pressure of at least 15 psi thus allowing friction and pressure losses, what will be added into the system to be able to provide a 15 psi?

Correct! Wrong!

May be used for hot and cold water distribution system within a building.

Correct! Wrong!

Shower threshold shall be of sufficient width to accommodate a minimum of door width of?

Correct! Wrong!

Horizontal plastic tube shall be supported by stiff metal or wood backing with hangers for 38 mm and smaller in diameter at its __________.

Correct! Wrong!

A kind of valve that shall be provided for each fixture.

Correct! Wrong!

Water supply inlet to receptors not protected by atmospheric vacuum breaker shall be protected by approved ________.

Correct! Wrong!

Fittings on screw pipe joint shall be_____ to the full bore of the pipe.

Correct! Wrong!

Excessive water pressure in excess of 80 psi (551 kpa) shall be provided with a device to the reduce the pressure to the required supply pressure.

Correct! Wrong!

Joints of lead pans or liners shall be______

Correct! Wrong!

Cleanout shall be provide at every ________ length.

Correct! Wrong!

Sixty (60) degree branches or offsets may be used only when installed in true

Correct! Wrong!

Material should not be used for continuous waste and overflows tailpiece or trap for urinal?

Correct! Wrong!

Valves over 51mm in size may be a ___________.

Correct! Wrong!

Support trap arm as close as possible to the trap, if the trap arm excess in _______.

Correct! Wrong!

Water closet flushometer tanks shall be protective against backflow by an approved device called ___________.

Correct! Wrong!

Cast iron fitting up to including 51 mm in size, when used in connection with potable water piping shall be ___________.

Correct! Wrong!

When potable water is discharged into the drainage system, it means than an approved air gap " with unobstructed atmospheric distance from the supply outlet and the top surface of the drainage inlet, but in no case shall the gap be less than 25 mm.

Correct! Wrong!

Tunnels shall have a clear height of______ above the pipe and shall be limited in length to ______the depth of a trench with a maximum length of _______. When pipe is driven, the drive pipe shall be at least ________than the pipe to be laid.

Correct! Wrong!

Horizontal lead pipe shall be supported by stiff metal or wooden backing at its _________.

Correct! Wrong!

Lawn sprinkler system shall be equipped with a listed and installed at discharge side of each of the last shutoff valve.

Correct! Wrong!

Air may be substitute for a water piping test for hot and cold with a minimum of_______ for a period of ________

Correct! Wrong!

Return bend vent pipe of a potable water storage tank shall be screened with a fined corrosion-resistant screen with opening not less than or nor more than __________.

Correct! Wrong!

Minimum water piping for hot and cold pressure test shall be test under a pressure of not less than_______ for a period of _______

Correct! Wrong!

Minimum section of water test for the DWV shall be_____ and shall be filled with water for a______ before the inspection starts

Correct! Wrong!

Water closet and urinal tanks shall be equipped with a listed?

Correct! Wrong!

No devices in a waterline supply system if the inlet/outlet is less than the _________ and __________.

Correct! Wrong!

Horizontal screw pipe, sized 19 mm and smaller in diameter shall be supported approximately?

Correct! Wrong!

Horizontal copper tubing, sized 38 mm and smaller in diameter shall be supported approximately?

Correct! Wrong!

How many fixture units shall be allowed for a continuous flow into a drainage system like sump pump, ejector and air conditioning equipment for every 0.063 l/s(1gpm)?

Correct! Wrong!

In the absence of local regulation, shower occupancies shall be provided with individual thermostatic mixing valve and shall be adjusted to deliver the maximum hot water temperature of ___________.

Correct! Wrong!

Cleanout may be omitted on a short horizontal drainage pipe installed at a slope of?

Correct! Wrong!

Over rim baths filler and other fixtures with effective opening not greater than 25 mm in diameter when affective by the walls.

Correct! Wrong!

Minimum distance between the door or entry to the drain opening of shower shall be?

Correct! Wrong!

Minimum air gaps for water distribution for lavatories and other fixtures with effective opening not greater than 13 mm in diameter when affected by the walls?

Correct! Wrong!

Valves up to and including 51mm in sized shall be _______ or other approved materials.

Correct! Wrong!

Buried copper tubing where possible shall be installed with ______.

Correct! Wrong!

All shower compartments, regardless in shape shall be capable of encompassing a

Correct! Wrong!

Minimum of building water service pipe?

Correct! Wrong!

Double sanitary tees may be used when the barrel of the fitting is at least two pipe sized larger than the largest ___________.

Correct! Wrong!

Pressure loss in a water line in such devices in a water supply system must be included in ______________.

Correct! Wrong!

Trenches of building drainage shall be backfilled in thin layers of ______m above the top of the pipe with clean earth which not contain materials which can the damage the pipe

Correct! Wrong!

Installations elevated for more than 1.52 m above the floor grade of a backflow prevention assembly shall be provided with ________ capable of supporting a tester or maintenance person.

Correct! Wrong!

Thickness of Copper pans or liners shall be at least?

Correct! Wrong!

All porcelain enamel surfaces on plumbing fixture shall be

Correct! Wrong!

No water closet and bidet shall be set closer than from its center to center of a similar fixtures?

Correct! Wrong!

Water pipes ,building sewer, and storm drainage constructed in clay material or not approved material for use with in a building shall not be run or laid in the __________.

Correct! Wrong!

An additional cleanout shall be provided on a horizontal line exceeding at angle of _______.

Correct! Wrong!

Master Plumber Reviewer No. 1
Good Luck. More reviewers on the way. Be sure to check back for updated reviewers. Thank you for participating in our free review materials quizzes. Please don't forget to share with your friends on Facebook.

Share your Results:

Please share this quiz to view your results.

The post Free Online Master Plumber Reviewer No. 1 appeared first on CONSTRUIRE.

]]>
https://myconstruire.com/master-plumber-reviewer-no-1/feed/ 0
Master Plumber Practice Test No. 1 https://myconstruire.com/master-plumber-practice-test-no-1/ https://myconstruire.com/master-plumber-practice-test-no-1/#respond Sat, 02 Oct 2021 02:00:44 +0000 https://myconstruire.com/?p=162 Master Plumber Practice Test Master plumber practice test or exam is a self-assessment test if you’re ready to take the Master Plumber’s Licensure Exam. Email address will only be collected for automatic release of scores. Loading…   related: Master Plumber’s review materials check: DPWH accredited contractor’s and consultants Materials Engineer

The post Master Plumber Practice Test No. 1 appeared first on CONSTRUIRE.

]]>
Master Plumber Practice Test

Master plumber practice test or exam is a self-assessment test if you’re ready to take the Master Plumber’s Licensure Exam. Email address will only be collected for automatic release of scores.

 

related: Master Plumber’s review materials

check: DPWH accredited contractor’s and consultants Materials Engineer

The post Master Plumber Practice Test No. 1 appeared first on CONSTRUIRE.

]]>
https://myconstruire.com/master-plumber-practice-test-no-1/feed/ 0